Accessories

 


The accessories on this page can be found in our
Product Catalog  as well. Just enter the order number or the short name of the product into the search function - you will be on the right side immediately.

 

   
   
NEW:
4DI-Monitor: Monitor for EDC drive interface 4DI
   
NEW:
Container for electronic mounting
   
NEW:
4FAD - Measurement amplifier with a
carrier frequency of 5kHz and A/D conversion
of  ±100.000 steps
   
   
4ETF - Measurement amplifier with a
carrier frequency of 5kHz and A/D conversion
of ±140.000 steps
   
4INC - Interface board with two incremental counters, 24 Volt I/Os (6 outputs, one relay and
5 inputs)
   
4IO - Interface board with 24 Volt I/Os
(6 outputs, one relay and 5 inputs)
   
4DA - Interface board with 
±10V analog output, 16 Bit 5V
   
4SSI - Synchron serial Interface
for magnetostrictive Sensor
   
4TAST - Interface for remote control panel TAST with 15 keys
   
TERM - I/O Terminal for 4TAST
with 22 outputs and 22 inputs with plug-in terminal
   
DEX - Option for 4DI or EDC60
with 16 Bit ±10V and digital command output
   
ANA - Analog output for 4ETF, 4FAD,
EDC60 and EDC120
   
DWT - Draw wire position transducer
0,82µm resolution for EDC60/120
   
SYNCH-Option - Option to synchronise
a second EDC120
   
Remote Machine Controls

It may be of advantage to operate testing instruments via separate keyboards. Therefore, DOLI offers several remote machine controls. They can be designed custom-made for OEM customers.

RMC - Remote machine control with
three keys and Digipoti

TAST - Remote machine control with 15 keys and Digipoti to be connected to 4TAST (without foil)

   
SGS - Sensor plugs
   

   
NEW:
4DI-Monitor: Monitor for EDC drive interface 4DI

(01457)

   

The 4DI-Monitor has been developed to quickly solve problems with the communication between measurement electronics and testing instrument. He will be connected to the 4DI drive interface of the EDC.

  • All incoming signals are represented by LEDs on the 4DI-Monitor, all kinds of switchs can be simulated.

  • Using the "short-circuit-plug" - which in fact replaces the testing instrument - the signals of the EDC will be shown exclusively.

  • The monitor can be connected between the EDC and the testing instrument, hence facilitating the trouble-shooting with the EDC as well as with the testing instrument.

The operative range of the 4DI-Monitor extends from the research&development over the production up to the service department.

 

 

   
NEW:
Container for electronic mounting
            

(01725)

 

 

Complete container with base shell and top shell (with multiple socket, without cable conduit, without EDC). Removable Mounting plate with top head rails and cable channels for an easy mounting of contactors or power amplifiers etc. outside of the shell. Earthing bar for all metal shields. Strain relief clamp and earthing bar for shielded cables.

 

   
NEW:
4FAD - Measurement amplifier with a carrier frequency
of 5kHz and A/D conversion of ±100.000 steps 

 (01520)

   

Fitting for strain gauges and inductive transducers (1.16 – 1,625V/V) and analog signals, 1ms detection rate, linearity 0,01%, accuracy 0,025%. The 4FAD fits for static and dynamic applications with a frequency of up to approx. 100Hz.

PDF-Download

 
   
4ETF - Measurement amplifier with a carrier frequency
of 5kHz and A/D conversion of ±140.000 steps

(00725)

   

Fitting for strain gauges and inductive transducers (116 - 1625 mV/V) and analogue signals, A/D Conversion ±140.000 at 20ms integration time, linearity 0,01%, Accuracy 0,025%

PDF-Download

 
   
4INC - Interface board with two incremental counters,
24 Volt I/Os (6 outputs, one relay and 5 inputs)

(01206)

   

Two incremental counters with digital quadruplication. The control adaptation happens via the sensor plug. The board offers 6 outputs with 24V/100mA, one output relay with change-over contact as well as 5 inputs with 24V-level.

   
4IO - Interface board with 24 Volt I/Os
(6 outputs, one relay and 5 inputs)

(01239)

   

The board offers 6 outputs with 24V/100mA, one output relay with change-over contact as well as 5 inputs with 24V-level.

   
4DA - Interface board with ±10V analog output, 16 Bit 5V

(01491)

   

±10V-output with a resolution of 16 bit. Application e.g. for Lo-approach with automatic strain transducers or clamping force control of hydraulic clamps.

   
4SSI - Synchron serial Interface for magnetostrictive Sensor

(01398)

   

   
4TAST - Interface for remote control panel TAST with 15 keys

(00887)

   

Interface board either for the remote control TAST with 15 keys and Digipoti or for the plug/screw-terminal TERM with 22 outputs and 22 inputs especially for larger control tasks.

   
TERM - I/O Terminal for 4TAST
with 22 outputs and 22 inputs with plug-in terminal

(01167)

   

I/O terminal with plug-in terminals for the application in e.g. instruments for the connection and poll of pneumatic valves etc.

   
DEX - Option for 4DI or EDC60
with 16 Bit ±10V and digitale command output

(01148)

   

Additional board for 4DI for a high resolution of the output (±15 Bit) with ±10V signal. Digital set value interface for 10kHz to 2MHz adjustable in eight steps.

   
ANA - Analog output for 4ETF, 4FAD, EDC60 and EDC120

(00766)

   

Analog output for the EDC basic units, load channel (DC-supply) or for 4ETF and 4FAD boards. ANA supplies a ±10V signal, that will be decoupled after the filter. This signal is not scaled; and there are no possibilities to do so.

   
DWT - Draw wire position transducer
0,82µm resolution for EDC60/120

(01011)

   

Draw wire transducer, cable length 5m, sensor plug 9IL (0792) already written and mounted on it.

   
SYNCH-Option -
Option to synchronise a second EDC120

(01442)

   

With this option, up to 32 EDCs can be polled synchronuously. The SYNCH Option contains an interface board and the necessary connections for the installation inside the EDC. As this option has a serial RS485-bus, an EDC connecting cable (1336) as well as a bus closing device for the start and the end (1337, 1404) are necessary in addition.

   
RMC - Remote machine control with three keys and Digipoti

(00706)

   

Remote Machine Control with the functions Up/Down/Stop and the Digital Potentiometer for the setup of the instrument. Magnetic housing, 2m cable.

   
TAST - Remote machine control with 15 keys and Digipoti
to be connected to 4TAST (without foil)

(00888)

 

 

   
SGS - Sensor plugs  
 

 

The problem is known: Load cell and calibration. 

Load cell, cable and plug are one part. If the identification and the calibration data is written into the plug, the transducer is interchangeable. For that reason, DOLI has sensor plugs available for strain gauge, LVDT, incremental, and other transducers and signals. Of course they are pre-set for several sensitivities.

 

 

   
   
   
 

© 2005 DOLI Elektronik