NEW:
4DI-Monitor: Monitor for EDC drive interface 4DI |
| |
|
 |
NEW:
Container for electronic mounting |
| |
|
 |
NEW:
4FAD - Measurement amplifier with a
carrier frequency of 5kHz and
A/D conversion
of ±100.000 steps |
| |
|
| |
|
 |
4ETF -
Measurement amplifier with a
carrier frequency of 5kHz and A/D conversion
of ±140.000 steps |
| |
|
 |
4INC -
Interface board with two incremental counters, 24 Volt I/Os (6
outputs, one relay and
5 inputs) |
| |
|
 |
4IO - Interface board with 24 Volt
I/Os
(6 outputs, one relay and 5 inputs) |
| |
|
 |
4DA - Interface board with
±10V analog output, 16 Bit 5V |
| |
|
 |
4SSI - Synchron serial
Interface
for magnetostrictive Sensor |
| |
|
 |
4TAST - Interface for remote
control panel TAST with 15 keys |
| |
|
 |
TERM - I/O Terminal for 4TAST
with 22 outputs and 22 inputs with plug-in terminal |
| |
|
 |
DEX - Option for 4DI or EDC60
with 16 Bit ±10V and digital command output |
| |
|
 |
ANA - Analog output for
4ETF, 4FAD,
EDC60 and EDC120 |
| |
|
 |
DWT - Draw wire position
transducer
0,82µm
resolution for EDC60/120 |
| |
|
 |
SYNCH-Option - Option to synchronise
a second EDC120 |
| |
|
 |
Remote
Machine Controls
It may be of advantage to operate testing instruments via separate
keyboards. Therefore, DOLI offers several remote machine controls.
They can be designed custom-made for OEM customers.
RMC - Remote machine control
with
three keys and Digipoti
TAST - Remote machine control
with 15
keys and Digipoti to be connected to 4TAST (without foil)
|
| |
|
 |
SGS - Sensor plugs |
| |
|
|
| |
|
 |
NEW:
4DI-Monitor: Monitor for EDC drive interface 4DI |
(01457) |
| |
The 4DI-Monitor
has been developed to quickly solve problems with the communication
between measurement electronics and testing instrument. He will be
connected to the 4DI drive interface of the EDC.
-
All incoming
signals are represented by LEDs on the 4DI-Monitor, all kinds of
switchs can be simulated.
-
Using the "short-circuit-plug"
- which in fact replaces the testing instrument - the signals of
the EDC will be shown exclusively.
-
The monitor can
be connected between the EDC and the testing instrument, hence
facilitating the trouble-shooting with the EDC as well as with
the testing instrument.
The operative range of the 4DI-Monitor extends from
the research&development over the production up to the service
department.

 |
| |
|
 |
NEW:
Container for electronic mounting
|
(01725) |
| |
Complete container with base shell and
top shell (with multiple socket, without cable conduit, without EDC).
Removable Mounting plate with top head rails and cable channels for
an easy mounting of contactors or power amplifiers etc. outside of
the shell. Earthing bar for all metal shields. Strain relief clamp
and earthing bar for shielded cables.

 |
| |
|
 |
NEW:
4FAD - Measurement amplifier with a carrier frequency
of 5kHz and A/D conversion of ±100.000 steps |
(01520) |
| |
Fitting for strain gauges and inductive
transducers (1.16 – 1,625V/V) and analog signals, 1ms detection
rate, linearity 0,01%, accuracy 0,025%. The 4FAD fits for static and
dynamic applications with a frequency of up to approx. 100Hz.

PDF-Download |
| |
 |
| |
|
 |
4ETF - Measurement amplifier
with a carrier frequency
of 5kHz and A/D conversion of
±140.000 steps |
(00725) |
| |
Fitting
for strain gauges and inductive transducers (116 - 1625 mV/V) and
analogue signals, A/D Conversion ±140.000 at 20ms integration time,
linearity 0,01%, Accuracy 0,025%

PDF-Download |
| |
 |
| |
|
 |
4INC -
Interface board with two incremental counters,
24 Volt I/Os (6
outputs, one relay and 5 inputs) |
(01206) |
| |
Two incremental counters with digital
quadruplication. The control adaptation happens via the sensor plug.
The board offers 6 outputs with 24V/100mA, one output relay with
change-over contact as well as 5 inputs with 24V-level.

 |
| |
|
 |
4IO - Interface board with 24 Volt
I/Os
(6 outputs, one relay and 5 inputs) |
(01239) |
| |
The board offers 6 outputs with
24V/100mA, one output relay with change-over contact as well as 5
inputs with 24V-level.

 |
| |
|
 |
4DA - Interface board with
±10V analog output, 16 Bit 5V |
(01491) |
| |
±10V-output with a resolution of 16 bit.
Application e.g. for Lo-approach with automatic strain transducers
or clamping force control of hydraulic clamps.

 |
| |
|
 |
4SSI - Synchron serial
Interface for magnetostrictive Sensor |
(01398) |
| |

 |
| |
|
 |
4TAST - Interface for remote
control panel TAST with 15 keys |
(00887) |
| |
Interface board either for the remote
control TAST with 15 keys and Digipoti or for the plug/screw-terminal
TERM with 22 outputs and 22 inputs especially for larger control
tasks.

 |
| |
|
 |
TERM - I/O Terminal for 4TAST
with 22 outputs and 22 inputs with plug-in terminal |
(01167) |
| |
I/O terminal with plug-in terminals for
the application in e.g. instruments for the connection and poll of
pneumatic valves etc.

 |
| |
|
 |
DEX - Option for 4DI or EDC60
with 16 Bit ±10V and digitale command output |
(01148) |
| |
Additional board for 4DI for a high
resolution of the output (±15 Bit) with ±10V signal. Digital set
value interface for 10kHz to 2MHz adjustable in eight steps.

 |
| |
|
 |
ANA - Analog output for
4ETF, 4FAD, EDC60 and EDC120 |
(00766) |
| |
Analog output for the EDC basic units,
load channel (DC-supply) or for 4ETF and 4FAD boards. ANA supplies a
±10V signal, that will be decoupled after the filter. This signal is
not scaled; and there are no possibilities to do so.

 |
| |
|
 |
DWT - Draw wire position
transducer
0,82µm
resolution for EDC60/120 |
(01011) |
| |
Draw wire transducer, cable length 5m,
sensor plug 9IL (0792) already written and mounted on it.

 |
| |
|
 |
SYNCH-Option -
Option to synchronise a second EDC120 |
(01442) |
| |
With this option, up to 32 EDCs can be
polled synchronuously. The SYNCH Option contains an interface board
and the necessary connections for the installation inside the EDC.
As this option has a serial RS485-bus, an EDC connecting cable
(1336) as well as a bus closing device for the start and the end
(1337, 1404) are necessary in addition.

 |
| |
|
 |
RMC - Remote machine control
with three keys and Digipoti |
(00706) |
| |
Remote
Machine Control with the functions Up/Down/Stop and the Digital
Potentiometer for the setup of the instrument. Magnetic housing, 2m
cable.

 |
| |
|
 |
TAST - Remote machine control
with 15
keys and Digipoti
to be connected to 4TAST (without foil) |
(00888) |
| |

 |
| |
|
 |
SGS - Sensor plugs |
|
| |
The problem is known: Load cell and calibration.
Load cell, cable and plug are one part. If the identification and
the calibration data is written into the plug, the transducer is
interchangeable. For that reason, DOLI has sensor plugs available
for strain gauge, LVDT, incremental, and other transducers and
signals. Of course they are pre-set for several sensitivities.
   |
| |
|
| |
|
| |
|
| |
©
2005 DOLI Elektronik
|
| |
|
| |
|